| Specification |
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Yuanchen;
Coil Number: 2;
Coil Structure: Round;
Winding Material: Copper;
Frequency: 50 Hz,60 Hz;
Input Voltage: 6kv,10kv,15kv,20kv35kv;
Output Voltage: 110V220V,380V,400V,440V,48 Ov;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Huawan Power;
Product Name: Oil Immersed Transformer;
Capacity: 200kVA;
Cooling System: Nature Air + Oil Cooling;
Connection: Delta or Star Connection;
Model Number: S11;
Winding Material: Copper, Aluminum;
Coil Structure: Toroidal;
Tap Changer: off Load Tap Changer;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: EI;
Brand: Hfy;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Dry Type Cast Resin Transformers;
Reference Standards: IEC60076;
Capacity: 2000kVA or Customized;
Rated H. V.: 34.5kV or Customized;
Rated L. V.: 0.48kV or Customized;
Impedance: 4 %;
Cooling Way: AN/AF;
Winding Material: Copper;
Core Materials: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: 125K;
Enclosure: IP20/IP23;
Accessories: Fans, Enclosure;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl Electric;
Type: Dry Type Cast Resin Transformers;
Reference Standards: IEC60076;
Capacity: 2000kVA or Customized;
Rated H. V.: 34.5kV or Customized;
Rated L. V.: 0.48kV or Customized;
Impedance: 4 %;
Cooling Way: AN/AF;
Winding Material: Copper;
Core Materials: Silicon Steel;
Insulation Level: as Per IEC Standard;
Vector Group: Dyn11;
Insulation Class: H-Class;
Temperature Rise: 125K;
Enclosure: IP20/IP23;
Accessories: Fans, Enclosure;
|