| Specification |
Type: Power;
Structure: Fixed Board;
Form: All- packaged Type;
Operation Voltage: Low Voltage;
Size: Customizable;
Application Range: Industry, Factories, Buildings, New Energy,etc;
Shell Material: Customizable;
Shell Protection Grade: IP30-IP66;
Brand: ABB, Chint, Siemens, Omron, Delixi, etc;
Rated Voltage: AC 380V/220V, 50Hz;
Rated Current: 100A, 250A, 400A, 630A, 800A, 1250A, 2000A;
Short-Time Withstand Current: 16ka, 25ka, 31.5ka, 50ka;
Rated Insulation Voltage: 660V;
Busbar System: Copper Bar (Tmy);
Power Factor: 0.8~0.95 (Lagging);
Cabinet Material: 1.5~2.0mm;
Installation Method: Floor-Mounted, Wall-Mounted;
Protection Type: Overload Protection, Short-Circuit Protection, etc;
Operation Mode: Manual Operation, Electric Operation (Optional);
Internal Separation: Functional Unit Separation;
Operating Temperature: -10℃~+40℃;
Altitude: ≤2000m;
|
Type: Explosion-Proof Box;
Structure: Protection;
Form: Partly-welded Type;
Operation Voltage: High Pressure, Low Pressure;
Size: Customizable;
Application Range: Oil, Chemical Industry, Natural Gas, Coal Mines;
Shell Material: Aluminum Alloy, Stainless Steel, Engineering Plast;
Shell Protection Grade: IP66;
Brand: Ztzn;
Function: Power Distribution Equipment in Hazardous;
Application: Industry, Gas Station, Refinery, Spray Booth, Haza;
Customized: Can Be Customized;
Alias 1: Explosion Proof Control Box, Distribution Box;
|
Form: All- packaged Type;
Operation Voltage: High Voltage;
Size: 1 Uint;
Application Range: Power Plants;
Shell Material: Stainless Steel;
Shell Protection Grade: IP56;
Altitude: No More Than 1000m;
Feature: Great Flexibility, Small Volume, Low Cost,Rapid;
Rated Voltage: 10kv/0.4kv;
Rated Frequency: 50Hz;
|
Type: Lighting;
Structure: Open Frame;
Form: All- packaged Type;
Operation Voltage: Low Voltage;
Size: Customized;
Application Range: Power Plants;
Shell Material: Steel Plate;
Shell Protection Grade: IP30;
Product Model: XL-21;
Rated Operating Voltage: AC380 AC660(V);
Rated Frequency: 50/60(Hz);
Rated Short-Time Withstand Current (1s): 50ka;
Rated Peak Withstand Current: 105ka;
Rated Insulation Voltage: 660V;
Ingress Protection: IP40/IP30;
Dimensions(W*D*H): 1700*700*370mm;
Rated Operating Voltage (V): 380;
Ated Insulation Voltage (V): 690;
Rated Working Current of Horizontal Busb: ≤2000;
Rated Short-Time Withstand Current RMS (: 30/63;
Enclosure Rating: IP30;
Dimensions (Hxwxd, mm: 400~1000X600~1000X1400~2200;
|
Type: Lighting;
Structure: Open Frame;
Form: All- packaged Type;
Operation Voltage: Low Voltage;
Size: Customized;
Application Range: Power Plants;
Shell Material: Steel Plate;
Shell Protection Grade: IP30;
Product Model: XL-21;
Rated Operating Voltage: AC380 AC660(V);
Rated Frequency: 50/60(Hz);
Rated Short-Time Withstand Current (1s): 50ka;
Rated Peak Withstand Current: 105ka;
Rated Insulation Voltage: 660V;
Ingress Protection: IP40/IP30;
Dimensions(W*D*H): 1700*700*370mm;
Rated Operating Voltage (V): 380;
Ated Insulation Voltage (V): 690;
Rated Working Current of Horizontal Busb: ≤2000;
Rated Short-Time Withstand Current RMS (: 30/63;
Enclosure Rating: IP30;
Dimensions (Hxwxd, mm: 400~1000X600~1000X1400~2200;
|