| Specification |
After-sales Service: 1 Year;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
|
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Customized: Customized;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Application: Laboratory Apparatus;
Warranty: 1 Years;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Optical System: Double-Beam Proportional Monitoring Optical System;
Measurement Mode: Transmittance, Absorbance, Energy, Reflectance;
Spectral Bandwidth: 2nm;
Wavelength Range: 190~1100nm;
Wavelength Accuracy: ≤ ± 0.5nm;
Wavelength Repeatability: ≤ 0.2nm;
Photometric Range: 0~999.9%T, -3A~3A, 0~9999c, -1.9999f;
Photometric Accuracy: ≤ ± 0.3%T(0~100%T) ≤ ± 0.002A(0~0.5A) ≤ ± 0.004A;
Photometric Repeatability: ≤ 0.15%T(0~100%T) ≤ 0.001A(0~0.5A) ≤ 0.002A(0.5~;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Application: Laboratory Apparatus;
Warranty: 1 Years;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Optical System: Double-Beam Proportional Monitoring Optical System;
Measurement Mode: Transmittance, Absorbance, Energy, Reflectance;
Spectral Bandwidth: 2nm;
Wavelength Range: 190~1100nm;
Wavelength Accuracy: ≤ ± 0.5nm;
Wavelength Repeatability: ≤ 0.2nm;
Photometric Range: 0~999.9%T, -3A~3A, 0~9999c, -1.9999f;
Photometric Accuracy: ≤ ± 0.3%T(0~100%T) ≤ ± 0.002A(0~0.5A) ≤ ± 0.004A;
Photometric Repeatability: ≤ 0.15%T(0~100%T) ≤ 0.001A(0~0.5A) ≤ 0.002A(0.5~;
|
After-sales Service: Online Technical Support;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Interferometer Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Wl Range (Nm): 190-900;
Spectrum Bandwidth: 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm;
Background Calibration Ability: Greater Than 30 Times;
RS232: Including;
Brand: Drawell;
Receptivity of The Wavelength: ≤0.04nm;
Base Line Stability: ≤0.002A/30min (Cu);
Characteristic Viscosity: 0.02μg/Ml/1% (Cu);
Checking Limit: 0.004μg/Ml (Cu);
Preciseness: 0.5%;
Grating: 1800 Lines/mm;
Inflamer: All-Metal Titanium Burner;
Atomizer: Effective Glass Atomizer;
Lamp Stand: 8;
|