After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Digital;
Installation: DIN-Rail Mounting;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: 333mv CT, Rogowski Coil;
Type: Power Meter;
Customized: Customized;
Input Type: External CT(333mv Only), External Rogowski Coil;
Programmable Digital Output: Alarm, 3 Tariff;
Power: 85~265V AC/DC;
Storage: 4 GB SD Card;
Poles Description: 3pH4w 3pH3w 1pH2w (L-N) 1pH2w(L-L) 1pH3w(L-L-N);
Device Application: Power Analysis, Tariff Meter;
Sampling Rate: 8K Samples Per Second;
Harmonic: 52th Max;
Data Acquisition Rate: 400ms;
Display Update Rate: 0.5s;
Transmission Mode: Modbus RTU, RS485 Port;
Primary Current Range: Adjustable From 0.1A to 9999A;
Voltage: 100V to 500V AC;
Frequency Range: 50/60Hz;
Display Screen: 2.0 Inch TFT Screen Display;
|
After-sales Service: We Can Provide Lifetime Maintenance;
Warranty: 1 Year;
Display: Digital;
Installation: Embedded Installation;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter, Smart Power Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Smart Power Meter;
Power Meter Connection: Terminal;
Type: Power Meter;
Customized: Customized;
Frequncy: 45-65Hz;
Harmonics Measurement: 2-31 Times;
Communication Protocol: Modbus RTU, Mqtt, 645-2007,Others;
Smart IoT: RS485(4G, WiFi, Lora, Lorawan);
Accuracy: Voltage& Current Level 0.2, Power Level 0.2;
|
After-sales Service: After-Sales Service Is Comprehensive;
Warranty: 1 Year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Reference Voltage: 3*220V;
Power Consumption: <10va;
Impedance: >2MΩ;
Accuracy Level: Error ±0.2%;
Input Current: 5(60);
Output Current: 1-Way, 2-Way Maximum 60A 3-Way 5A;
Grid Frequency: 45-65Hz Error ±0.2%;
Electricity: Active Energy Level 1;
Power Pulse Output: Active Optocoupler Output;
Pulse Constant: 1200imp/Kwh;
Interface and Communication Protocol: RS485 Modbus Dl/T 645-2007;
Communication Address Range: Communication Address Range;
Baud Rate: Support 1200BPS~9600BPS;
Operating Temperature: -25℃~60℃;
Storage Temperature: -40℃~70℃;
|
After-sales Service: After-Sales Service Is Comprehensive;
Warranty: 1 Year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Reference Voltage: 3*220V;
Power Consumption: <10va;
Impedance: >2MΩ;
Accuracy Level: Error ±0.2%;
Input Current: 5(60);
Output Current: 1-Way, 2-Way Maximum 60A 3-Way 5A;
Grid Frequency: 45-65Hz Error ±0.2%;
Electricity: Active Energy Level 1;
Power Pulse Output: Active Optocoupler Output;
Pulse Constant: 1200imp/Kwh;
Interface and Communication Protocol: RS485 Modbus Dl/T 645-2007;
Communication Address Range: Communication Address Range;
Baud Rate: Support 1200BPS~9600BPS;
Operating Temperature: -25℃~60℃;
Storage Temperature: -40℃~70℃;
|
After-sales Service: After-Sales Service Is Comprehensive;
Warranty: 1 Year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Reference Voltage: 3*220V;
Power Consumption: <10va;
Impedance: >2MΩ;
Accuracy Level: Error ±0.2%;
Input Current: 5(60);
Output Current: 1-Way, 2-Way Maximum 60A 3-Way 5A;
Grid Frequency: 45-65Hz Error ±0.2%;
Electricity: Active Energy Level 1;
Power Pulse Output: Active Optocoupler Output;
Pulse Constant: 1200imp/Kwh;
Interface and Communication Protocol: RS485 Modbus Dl/T 645-2007;
Communication Address Range: Communication Address Range;
Baud Rate: Support 1200BPS~9600BPS;
Operating Temperature: -25℃~60℃;
Storage Temperature: -40℃~70℃;
|