| Specification |
Max Diameter of Workpiece: 900mm;
Mass Scope of Workpiece: <900kg;
Type: Strength Testing Machine;
Maxcapacity: >1000KN;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Static Load;
Display: LCD/Digital/LED;
Control: Pushbutton/Computer;
Power Source: at Customized;
Capacity: 10kVA~50000kVA or Customized;
Operation Interface: Fully English Interface;
Test Item: No Load, DC, Insulation, Heat Run, Power Frequency;
Control Mode: Auto & Manual;
Test Items: Turn Ratio, DC Winding, Noload Loss Load Impedance;
|
After-sales Service: Suppor for Lifelong;
Warranty: 12 Months or Extended;
Type: Transformer Tester;
Test Range: (-100dB) - (+20dB);
Frequency Accuracy: <0.01%;
Product Name: Sfra;
Model: Hm5010;
Scan Mode 1: Linear Scanning Distribution;
Scan Mode 2: Segment Frequency Scanning;
Frequency Scanning Measurement Range: (0.5kHz) - (1MHz),;
Scanning Points: 2000;
Amplitude Measurement Accuracy: 0.1dB;
Scanning Frequency Accuracy: 0.01%;
Signal Input Impedance: 1mΩ;
Signal Output Impedance: 50Ω;
Signal Output Amplitude: ± 20V;
Test Repetition Percent: 99.9%;
|
After-sales Service: Suppor for Lifelong;
Warranty: 12 Months or Extended;
Type: Transformer Tester;
Accuracy Grade: 0.01%;
Display: LCD;
Control: Computer Control;
Weight: 18kg;
Power Source: AC220V;
Test Range: (-100db) - (+20db);
Frequency Accuracy: <0.01%;
Product Name: Sfra;
Model: Hm5010;
Scan Mode 1: Linear Scanning Distribution;
Scan Mode 2: Segment Frequency Scanning;
Frequency Scanning Measurement Range: (0.5kHz) - (1MHz),;
Scanning Points: 2000;
Amplitude Measurement Accuracy: 0.1db;
Scanning Frequency Accuracy: 0.01%;
Signal Input Impedance: 1MΩ;
Signal Output Impedance: 50ω;
Signal Output Amplitude: ± 20V;
Test Repetition Percent: 99.9%;
|
After-sales Service: Suppor for Lifelong;
Warranty: 12 Months or Extended;
Type: Transformer Tester;
Accuracy Grade: 0.5;
Display: LCD;
Control: Computer Control;
Weight: 15;
Power Source: AC220V;
Test Range: (-100db) - (+20db);
Frequency Accuracy: <0.01%;
Product Name: Sfra;
Model: Hm5010;
Scan Mode 1: Linear Scanning Distribution;
Scan Mode 2: Segment Frequency Scanning;
Frequency Scanning Measurement Range: (0.5kHz) - (1MHz),;
Scanning Points: 2000;
Amplitude Measurement Accuracy: 0.1db;
Scanning Frequency Accuracy: 0.01%;
Signal Input Impedance: 1MΩ;
Signal Output Impedance: 50ω;
Signal Output Amplitude: ± 20V;
Test Repetition Percent: 99.9%;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: CT/PT Analyzer;
Accuracy Grade: 0.2%;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: <9kg;
Power Source: AC220V;
Usage: Class P/Tp CT & Vt;
Output: 0~100vrms,12arms,36A(Peak Value);
Voltage Measurement Accuracy: ±0.2%;
CT Ratio: Range:1~30000;Accuracy:±0.2%;
PT Ratio: Range:1~10000;Accuracy:±0.2%;
Phase: Range:±5min;Accuracy:0.5min;
DC Resistance: Range:0~300Ω;Accuracy:2%±2mΩ;
Burden: Range:0~300va;Accuracy:2%±0.2va;
Standard: IEC,Iee;
Model Name: CT PT Analyzer;
Model Type: Hmcop-100p;
Application: Test for Protection Class CT, Protection Class PT;
Power Supply: AC220V;
PT Ratio Accuracy: ±0.2%;
|