| Specification |
After-sales Service: Support;
Warranty: 1 Year;
Accuracy: 1.0g;
Maximum Measurement Range: 5000g;
Density Meter Type: Transmission-type Density Meter;
Viscometer Type: Manual;
Density Meter Principle: Float-type Density Meter;
Test Density: Grains;
Display: Digital;
Control: Manual Control;
Index Value: 1.0g;
Volume Weight Cylinder Diameter: 88.50(±0.05)mm;
Measurement Method: Combined Measurement;
Configuration: One Host and One Set of Accessories;
|
After-sales Service: 24 Hours Online Service;
Warranty: 1year;
Accuracy: ± 1.5%;
Maximum Measurement Range: 1.45 — 1.85 G /Cm³;
Density Meter Type: Transmission-type Density Meter;
Viscometer Type: Tuning Fork Concentratic;
Density Meter Principle: Vibrating Density Meter;
Viscometer Reproducibility: ± 0.0002 G /Cm³;
Measurement Range: Temperature: 0c-100℃;
Working Environment: -10℃-+55℃;
Maximum Working Pressure: 10MPa (100 Bar or 1450 Psi or 102 Kgf/Cm ²);
Fluid Viscosity Range: 0-200 Cp;
Process Temperature: 0.0001 G/ Cm³/ Per ℃(0.1 Kg/M ³/ Per ℃);
Built-in Temperature: PT100;
Contact Material: SUS 316L, Hastelloy C22, Hastelloy B3, Zirconium a;
Electrode Coating: Standard Type (Uncoated), PTFE Coated;
Power Supply Voltage: 24V DC;
Output Accuracy: 4-20 Ma: ±0.003 G/Cm³ (0.65 — 1.0 G/Cm³) ±0.004 G/Cm³ (1.0;
Output Repeatability: ± 0.05% Fs;
Communication Method: RS485 Protocol;
Process Connection: Flange Type, Sanitary Type, Thread Type;
Protection Grade: IP65;
Shell: Aluminiumn Alloy;
|
After-sales Service: 24 Hours Online Service;
Warranty: 1year;
Accuracy: ± 1.5%;
Maximum Measurement Range: 1.45 — 1.85 G /Cm³;
Density Meter Type: Transmission-type Density Meter;
Viscometer Type: Tuning Fork Concentratic;
Density Meter Principle: Vibrating Density Meter;
Viscometer Reproducibility: ± 0.0002 G /Cm³;
Measurement Range: Temperature: 0c-100℃;
Working Environment: -10℃-+55℃;
Maximum Working Pressure: 10MPa (100 Bar or 1450 Psi or 102 Kgf/Cm ²);
Fluid Viscosity Range: 0-200 Cp;
Built-in Temperature: PT100;
Contact Material: SUS 316L, Hastelloy C22, Hastelloy B3, Zirconium a;
Electrode Coating: Standard Type (Uncoated), PTFE Coated;
Power Supply Voltage: 24V DC;
Output Accuracy: 4-20 Ma: ±0.003 G/Cm³ (0.65 — 1.0 G/Cm³) ±0.004 G/Cm³ (1.0;
Output Repeatability: ± 0.05% Fs;
Communication Method: RS485 Protocol;
Process Connection: Flange Type, Sanitary Type, Thread Type;
Protection Grade: IP65;
Shell: Aluminiumn Alloy;
Process Temperature: 0.0001 G/ Cm³/ Per ℃(0.1 Kg/M ³/ Per ℃);
|
After-sales Service: Installation Guidance;
Warranty: 12-Month;
Accuracy: ±0.5%;
Maximum Measurement Range: 1000000 MPa. S;
Density Meter Type: Vibration Viscometer;
Viscometer Type: Vibration;
Density Meter Principle: Vibrating Density Meter;
Test Density: Light;
Viscometer Reproducibility: ±0.2%;
Viscometer Rotor Number: -;
Viscometer Rotor Speed: -;
Viscometer Rotor Specifications: -;
Sensor Temperature Resistance Range: <500 ℃;
Signal Response Time: 2s;
Temperature Accuracy: 0.2%;
Sensor Pressure Range: <25MPa Customized;
Material: 316 Stainless Steel (Standard);(Other Optional);
Environmental Level: IP68;
Other: Customizable;
Power Supply: 24V DC;
|
After-sales Service: Installation Guidance;
Warranty: 12-Month;
Accuracy: ±0.5%;
Maximum Measurement Range: 1000000 MPa. S;
Density Meter Type: Vibration Viscometer;
Viscometer Type: Vibration;
Density Meter Principle: Vibrating Density Meter;
Test Density: Light;
Viscometer Reproducibility: ±0.2%;
Viscometer Rotor Number: -;
Viscometer Rotor Speed: -;
Viscometer Rotor Specifications: -;
Sensor Temperature Resistance Range: <500 ℃;
Signal Response Time: 2s;
Temperature Accuracy: 0.2%;
Sensor Pressure Range: <25MPa Customized;
Material: 316 Stainless Steel (Standard);(Other Optional);
Environmental Level: IP68;
Other: Customizable;
Power Supply: 24V DC;
|