| Specification |
Task: Program;
Structure: Closed-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control;
Condition: Used;
Customized: Non-Customized;
Material: Plastic;
Degree of Protection: IP 54;
Size: 302*240*120mm;
Unit Weight: 2.8kgs;
Control Characteristic: Double Liquid Level Control/Pressure Control;
Control Method: Manual/Auto;
Rated Ouput Power: 0.75-4kw/5.5-11kw/15kw;
Trip Response Time of Over Load: 5sec-5min;
Trip Response Time of Open Phase: <2sec;
Trip Response Time of Short Circuit: <0.1sec;
Trip Response Time of Under/Over Voltage: <5sec;
|
Task: Following;
Structure: Open-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Monitoring;
Condition: New;
Customized: Customized;
Material: Plastic;
Item No: DIN1X1 Isoem-A7- P2- O9;
Input Signal: 0- Positve and Negtive 20mA;
Auxiliary Power: 12V;
Output Signal: Negtive 5V to Positve 20;
Accuracy: 0.2% /0.5%;
Operating Temperature: -25 ~ +70degree;
Operating Humidity: 10 ~ 90% (Non-Condensing);
Storage Temperature: -45 ~ +80degree;
Storage Humidity: 10 ~ 95% (Non-Condensing);
Isolation Voltage: 3000V;
|
Task: Following;
Structure: Open-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Monitoring;
Condition: New;
Customized: Customized;
Material: Plastic;
Item No: DIN1X1 Isoem-a- P- O;
Input Signal: 0-5V, 0-10V, 0-75mv., 4-20mA, 0-20mA, etc;
Auxiliary Power: 5V,12V, 15V, 24VDC, 220VAC, etc.;
Output Signal: 0-20mA ,4-20mA, 0-10mA, 0-5V, 0-10V, etc;
Accuracy: 0.2% /0.5%;
Operating Temperature: -25 ~ +70degree;
Operating Humidity: 10 ~ 90% (Non-Condensing);
Storage Temperature: -45 ~ +80degree;
Storage Humidity: 10 ~ 95% (Non-Condensing);
Isolation Voltage: 3000V;
|
Task: Adjust;
Structure: Open-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Protection;
Condition: New;
Customized: Customized;
Material: Plastic;
Item No.: Isoem U(a)-P-O-O;
Input Signal: Voltage or Current;
Output Signal: Voltage or Current;
Auxiliary Power: DC5V\12V\24V;
Accuracygrade: 0.2 %;
Work Temperature: -45 ~ +85degree;
Work Humidity: 10 ~ 90% (Non-Condensation);
Storage Temperature: -45 ~ +70 Degree;
Isolation: Vin/Vout1/Vout 2/Power;
Warranty Time: Two Years;
|
Task: Adjust;
Structure: Open-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Protection;
Condition: New;
Customized: Customized;
Material: Plastic;
Item No.: Isoem U1-P1-O1-O2;
Input Signal: 0-5V;
Auxiliary Power: 24V;
Output Signal1: 4-20mA;
Output Signal2: 0-20mA;
Accuracygrade: 0.2 %;
Work Temperature: -45 ~ +85degree;
Work Humidity: 10 ~ 90% (Non-Condensation);
Storage Temperature: -45 ~ +70 Degree;
Warranty Time: Two Years;
|