| Specification |
Type: Wall-Mounted Current Type;
Measuring Medium: Temperature;
Site Display: Not Site Display;
Accuracy: 0.5%FS;
IP Rating: IP65;
Customized: Customized;
Sensor Type: Temperature Sensor;
Temperature: -40~1500℃;
Temp Accuracy: 0.5%FS;
Long-term Stability: 0.2%FS/year;
Supply: 24VDC;
Output: 4~20mADC or Three wire Voltage;
Working Temp: -30~70℃;
Storage Temp: -30~85℃;
Electrical Connection: Hirschmann; Cable Outlet;
Protection of Shell: IP65;
|
Type: Network Type;
Measuring Medium: Temperature;
Display Type: LCD;
Site Display: Site Display;
Accuracy: 0.1c;
IP Rating: IP56;
Customized: Customized;
Chipset: 4G/Nb-IoT/Lora;
Protection Rating: IP67;
Equipment Bearing,Pipeline,: Typical Application Cold Chain Logistics;
Power Source: DC 24V// Built-in Lithium Battery;
Explosion Proof: Iecex;
Probe Material: 316 Stainless Steel;
Typical Application: Equipment Bearing,Pipeline, Cold Chain Logistics;
Power Supply: 24V DC/Built-in Lithium Battery;
Protocol: Wirelesshart;
Battery Life: 5 Years Daily Reporting;
Sensor Type: PT100 Rtd/Type K Thermocouple;
Output Signal: 4G/Nb-Lot/Lora;
Temperature Range: -200c~+600c;
Antennas: External Rod Antenna;
|
Type: Insert Type;
Measuring Medium: Temperature;
Display Type: /;
Site Display: Not Site Display;
Accuracy: 0.2%, 0.5%;
IP Rating: IP66;
Customized: Customized;
Product Type: Modular type, rail type;
Housing Structure: Single Chamber;
Housing Material: High pressure cast aluminum or stainless steel;
Input Voltage: 12~35VDC, with polarity reversal protection;
Output Signal: 4~20mA, HART;
Cable Entry: 1/2"NPT or M20×1.5;
Process Temperature: -112~2932℉(-200~1800℃);
|
Type: Insert Type;
Measuring Medium: Temperature;
Display Type: /;
Site Display: Not Site Display;
Accuracy: 0.2%, 0.5%;
IP Rating: IP66;
Customized: Customized;
Product Type: Modular type, rail type;
Housing Structure: Single Chamber;
Housing Material: High pressure cast aluminum or stainless steel;
Input Voltage: 12~35VDC, with polarity reversal protection;
Output Signal: 4~20mA, HART;
Cable Entry: 1/2"NPT or M20×1.5;
Process Temperature: -112~2932℉(-200~1800℃);
|
Type: Insert Type;
Measuring Medium: Temperature;
Display Type: /;
Site Display: Not Site Display;
Accuracy: 0.2%, 0.5%;
IP Rating: IP66;
Customized: Customized;
Product Type: Modular type, rail type;
Housing Structure: Single Chamber;
Housing Material: High pressure cast aluminum or stainless steel;
Input Voltage: 12~35VDC, with polarity reversal protection;
Output Signal: 4~20mA, HART;
Cable Entry: 1/2"NPT or M20×1.5;
Process Temperature: -112~2932℉(-200~1800℃);
|