| Specification |
After-sales Service: Yes;
Warranty: 2 Years;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Static Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Auxiliary Power: AC85V-265V, DC100V-350V,DC24V, DC48V;
Interface: RS485;
Protocol: Modbus-RTU;
|
After-sales Service: Yes;
Warranty: 1year;
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use;
Electric Equipment: Three-phase Three-wire;
Theory: Electronic Meter;
Power Meter Connection: Feed-through Type;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Customized;
Interface: RS485;
Protocol: Modbus;
Auxiliary Power: AC85-265V, DC100-300V;
Temperature Measure: 24 Channels PT100/Ntc, 1 Channel Humidity;
Alarm: 2do;
|
After-sales Service: Yes;
Warranty: 2years;
Display: Digital;
Usage: Multi-Functional Energy Meter;
Theory: Electronic Meter;
Type: Energy Meter;
Customized: Customized;
Accuracy Class: 0.5;
Max. Current: 50mA CT;
Measuring Energy: 0-999999.9 Kwh;
Rated Current: 50mA CT;
Application: Electric Power, Industrial, Household;
Display Type: LCD;
Operating Temperature: -20-55;
|
Display: Digital;
Usage: Multi-Functional Energy Meter;
Electric Equipment: Three Phase;
Theory: Electronic Meter;
Type: Energy Meter;
Accuracy Class: 0.5;
Max. Current: 80 a;
Communication: RS485 (Modbus-RTU);
Operating Temperature: -25℃~55℃;
Output Voltage: AC 3X220V/380V;
AC 3X220V/380V: 3-Phase AC Kwh, Kvarh, U, I, P, Q, S, PF, F;
Frequency: 45~65Hz;
Rated Current: AC 3X10(80)a (Direct Connect); 3X1(6)a (Via Cts);
Multi-Rate: 4 Tariff Rates;
Harmonic: 2~31st and Total Harmonic;
|
Display: Digital;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Continuous Wave;
Type: Energy Meter;
Customized: Non-Customized;
Accuracy Class: 1.0;
Measuring Voltage: 220V, 230V, 240V;
Measurement of Kwh: Positive and Negative Active Kwh, Reactiv Kwh;
Measurement of Electrical Parameters: U, I, P, Q, S, PF, F, Kwh, etc..;
Input Current: 10(80)a;
LCD Display: 8 Bits Section LCD Display, Background Light;
Multi-Tariff: 4 Time Zones, 14 Time Interval by Day and 4 Tariff;
Recording: Frozen Data on Last 48 Months, Last 90 Days;
|