| Specification |
Theory: Latching Relay;
Usage: Electricity Meter;
Phase: 1;
Electricity Type: Ac;
Number of Pole: 1;
Load: High Power Relay;
Protective Characteristics: Enclosed Relay;
Action Principle: Electromagnetic Type;
Size: Miniature;
Type: Electric Parameter Relay;
Contact Form: 1A, 1b;
Max.Switching Current: 60A;
Coil Type: Single Coil or Double Coils;
Coil Voltage: 5VDC, 6VDC, 9VDC, 12VDC, 24VDC, 48VDC;
Standard: IEC62055-31 UC1;
Rosh: Rosh Compliant;
|
Theory: Time Relay;
Usage: Turn on or Break a Circuit;
Phase: None;
Electricity Type: AC/DC;
Number of Pole: None;
Load: Medium Power Relay;
Protective Characteristics: Open Relay;
Action Principle: Electronic Type;
Size: Standard;
Type: Time Relay;
Delay Range: 0.1s~99h;
Installation: Unit, panel and 35mm rail mounting with different;
Contact capacity: 3A AC250V (resistive);
Repeat Error: ≤ 1%;
|
Theory: Solid State Relay;
Usage: Lathe Relay, Industrial Automation Control Equipment;
Phase: None;
Electricity Type: DC/AC;
Number of Pole: None;
Load: 24-440VAC;
Protective Characteristics: Open Relay;
Action Principle: Electronic Type;
Size: 30.6×12.8×33mm;
Type: Electric Parameter Relay;
Control Voltage: 3-32VDC;
Control Current: 5-25mA;
Load Voltage: 24-440VAC;
Load Current: 1A, 2A,3A, 4A, 5A;
on-State Voltage Drop: DC≤1.2VAC AC≤1.6VAC;
|
Theory: Level Relay;
Usage: Water supply/ Drainage;
Phase: None;
Electricity Type: AC/DC;
Number of Pole: None;
Load: Standard;
Protective Characteristics: Enclosed Relay;
Action Principle: Electronic Type;
Size: Miniature;
Type: Non-Electric Parameter Relay;
Operation Mode: Water Supply and Drainage;
Water control distance: ≤ 100 metres;
Contact form: One set of NO and NC;
Contact capacity: 3A AC250V (resistive);
|
Theory: Electromagnetic Relay;
Usage: Household Appliances Relay, Communication Relay, Industrial Control Equipment;
Phase: 1 or 3 Phase;
Electricity Type: AC /DC;
Number of Pole: 1,2,3.;
Load: 1A/ 120VAC 2A / 24VDC;
Protective Characteristics: Sealed Relay;
Action Principle: No/Nc;
Size: Miniature;
Type: Electric Parameter Relay;
Contact Form: 2c;
Contact Resistance: 100 MΩ;
Max. Switching Voltage: 240VAC/60VDC;
Contact Material: Silver Alloy;
Insulation Resistance: 1000 MΩ 500 VDC;
Operate Time: Max. 6 Ms;
Release Time: Max. 4 Ms;
Humidity: 35% ~ 85%Rh;
Ambient Temp: -40℃ ~ +85℃;
Dielectric Strength: 1000VAC,Between Coil to Contact;
Dielectric Strength2: 500VAC,Between Open Contacts;
Shock Resistance: Functional: 20g;.Destructive 100g;
Electrical Life: 1×100000 OPS (at Rated Coil Voltage);
Mechanical Life: 1×1000000 OPS;
|