| Specification |
After-sales Service: 1 Year;
Principle: Static Pressure Measuring;
Range: 0-5m;
Measurement Accuracy: 0.5%;
Accuracy: 0.5%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: SS304;
Process Temperature: /;
Type: Submersible;
Contact: Contact;
Production Process: Ceramics;
Material: Stainless Steel;
IP Rating: IP68;
Customized: Customized;
Output Signal Type: Customizable;
Feature: Good Stability and Accuracy;
Range: 0~1....50m.....500m;
Output Signal: 4~20mA (Default), 0~5V, 0~10V (Customized);
Measurement Accuracy: 0.5% (0.2% Can Be Customized);
Nonlinear: ≤0.5fs%;
Repeatability: ≤0.2fs%;
Zero Drift: ≤0.2%Fs/4h;
Temperature Drift: ≤0.04%Fs/℃;
Stability: ≤0.2%Fs/Year;
Operating Voltage: 24VDC (Default), 12V, 5V (Customized);
Compensated Temperature: 0~50℃;
Operating Temperature: -20~70℃ (Recommended Below 50℃);
Overload Capacity: 300%;
Measuring Medium: >1×10^8 Pressure Cycle (25℃);
Shell Material: Various Liquids Compatible with 304;
Diaphragm Material: 316L Stainless Steel;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD D;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD D;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD D;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|
After-sales Service: Good;
Principle: Gas Sensors;
Range: 0-3m;
Measurement Accuracy: ±3mm;
Accuracy: 0.2%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: SS360L;
Process Temperature: Standard;
Float Material: Polyurethane Foam;
Thrust Screw Material: Brass;
Body G1" Material: Brass;
Washer: Plastic;
|