| Specification |
Installation Type: Wall-Mounted Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Digital Type;
Production Process: Integration;
Measuring Medium: Temperature;
IP Rating: IP65;
Customized: Customized;
Calibration: Type K / J / E / N / T / R / S / B;
Usage: Industrial;
Accuracy: Class I, II;
Theory: Temperature Controller;
Sheath Material: Stainless Steel or Ceramic;
Packaging: Carton or Wooden Case;
Sample: Available;
Temperature Range: 0-1300c;
|
Installation Type: on Table;
Sensing Type: Thermocouple;
Contact: Contactless;
Output Signal Type: Digital Type;
Production Process: Normal Wirewound;
Material: Carbon Humidity;
Measuring Medium: CO2;
IP Rating: IP55;
Customized: Non-Customized;
Color: White or Black;
Size: 9X7X3.5cm;
Detector: CO2 Temp and Humi;
Weight: 106g;
Charging Port: DC5V Type C;
Battery: 1200hma;
Sensor: Infrared Sensor;
Test Range: 400-5000ppm;
Display: LED+LCD+Backlight;
Warranty: 1 Year;
|
Installation Type: Tee Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Normal Wirewound;
Material: Carbon Humidity;
Measuring Medium: Temp, Humidity and Pressure;
IP Rating: IP65;
Customized: Customized;
Temp Range: -40-60℃;
Humidity Range: 0-100%Rh;
Pressure Range: 10-110kpa(100-1100mbar);
Output: 4-20mA,0-10V,RS485, Iic,SDI-12;
Supply: 5VDC, 12-24VDC;
Current Consumption: <20mA;
Radiation Shield(Optional): Rk95-01,11 Plates,M25*1.5;
Cable Length: 1.5m Standard;
Operating Temperature: -40℃-+80℃;
|
Installation Type: Tee Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Normal Wirewound;
Material: Carbon Humidity;
Measuring Medium: Temp, Humidity and Pressure;
IP Rating: IP65;
Customized: Customized;
Temp Range: -40-60℃;
Humidity Range: 0-100%Rh;
Pressure Range: 10-110kpa(100-1100mbar);
Output: 4-20mA,0-10V,RS485, Iic,SDI-12;
Supply: 5VDC, 12-24VDC;
Current Consumption: <20mA;
Radiation Shield(Optional): Rk95-01,11 Plates,M25*1.5;
Cable Length: 1.5m Standard;
Operating Temperature: -40℃-+80℃;
|
Installation Type: Tee Type;
Sensing Type: Thermocouple;
Contact: Contact;
Output Signal Type: Analog Type;
Production Process: Normal Wirewound;
Material: Carbon Humidity;
Measuring Medium: Temp, Humidity and Pressure;
IP Rating: IP65;
Customized: Customized;
Temp Range: -40-60℃;
Humidity Range: 0-100%Rh;
Pressure Range: 10-110kpa(100-1100mbar);
Output: 4-20mA,0-10V,RS485, Iic,SDI-12;
Supply: 5VDC, 12-24VDC;
Current Consumption: <20mA;
Radiation Shield(Optional): Rk95-01,11 Plates,M25*1.5;
Cable Length: 1.5m Standard;
Operating Temperature: -40℃-+80℃;
|