| Specification |
After-sales Service: Online Techinical;
Warranty: 12 Months;
Accuracy: ±0.6-1%;
Main Application: Water, Wastewater;
Size: DN15 to DN1200;
Sensor: Plug-in;
Application: Building HVAC Systems, Thermal Power Plants;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Acoustics;
Measurement Object: Closed Pipeline;
Humidity: 99% Rh, Non-Condensing;
Transmitter: Aluminum Alloy, IP65;
Display: 320*480 Color TFT Display;
Power Supply: 10 to 36 VDC / 90 to 245 VAC;
|
Accuracy: ±0.50%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil;
Size: 25mm~5000mm;
Sensor: Clamp-on/External;
Application: Industrial Production;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Transit Time;
Flow Range: ±0.01m/S ~ ±12m/S;
Repeatability: 0.15% of Measured Value;
Linerarity: ±0.5%;
Analog Output: 4~20mA, Max Load 750ω;
Pulse Output: 0~9999Hz, Oct, (Min. and Max. Frequency Is Adjust;
Realy Output: Spst, Max 1Hz,(1A@125VAC or 2A@30VDC);
Communication: RS232&RS485;
Data Logging: 8g SD Card High Memory Data Logging;
Power Supply: 90 to 245 VAC, 48 to 63 Hz. or 10 to 36VDC;
Keypad: 22 Keys with Tactile Action;
Display: 40 Character, 2 Line (20×2),Back Lit LCD.;
Transmitter Temperature: -40℃~60℃;
Transducer Temperature: -40℃~80℃;
Humidity: up to 99% Rh,Non-Condensing;
Transmitter: NEMA 4X (IP65), Die-Cast Aluminum;
|
Accuracy: ±1.0%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil;
Size: 25mm~1200mm;
Sensor: Clamp-on/External;
Application: Environmental Protection;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Transit Time;
Measurement Object: Closed Pipeline;
Flow Range: ±0.01m/S ~ ±5m/S;
Pipe Material: Carbon Steel,Stainless Steel,PVC,Ect;
Output: Oct Pulse Output:0~5000Hz;
Analog Output: 4~20mA,Max Load 750ω;
Communication Interface: RS485 Modbus;
Power Supply: 10~36VDC/1A;
Keypad: 16(4×4)Key with Tactile Action;
Display: 20×2 Lattice Alphanumeric, Back Lit LCD;
Transmitter Temperature: -10℃~50℃;
Transducer Temperature: 0℃~80℃;
Humidity: up to 99% Rh,Non-Condensing;
Transmitter: PC/ABS,IP65;
Transducer: Encapsulated Design,IP68;
Transducer Cable: Standard Cable Length:30FT(9m);
|
Accuracy: ±1.0% of Measured Value;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil;
Size: DN25~DN1200;
Sensor: Clamp-on/External;
Application: Aquaculture Automation Equipment;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Transit Time;
Measurement Object: Closed Pipeline;
Pipe Material: Carbon Steel,Stainless Steel,PVC Ect;
Outputs: Oct Pulse Output:0~5000Hz.;
Analog Output: 4~20mA,Max Load 750Ω
Communication Interface: RS485 Modbus;
Power Supply: 10~36VDC/1A;
Keypad: 16(4×4)Key with Tactile Action;
Display: 20×2 Lattice Alphanumeric, Back Lit LCD.;
Temperature: Transducer:0℃~80℃;
Humidity: up to 99% Rh,Non-Condensing;
Transmitter: PC/ABS,IP65;
Transducer: Encapsulated Design,IP68;
Transducer Cable: Standard Cable Length:30FT(9m);
|
Accuracy: ±1.0%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil;
Size: 25mm~1200mm;
Sensor: Plug-in;
Application: Environmental Protection;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Transit Time;
Measurement Object: Closed Pipeline;
Flow Range: ±0.01m/S ~ ±5m/S;
Pipe Material: Carbon Steel,Stainless Steel,PVC,Ect;
Output: Oct Pulse Output:0~5000Hz;
Analog Output: 4~20mA,Max Load 750ω;
Communication Interface: RS485 Modbus;
Power Supply: 10~36VDC/1A;
Keypad: 16(4×4)Key with Tactile Action;
Display: 20×2 Lattice Alphanumeric, Back Lit LCD;
Transmitter Temperature: -10℃~50℃;
Transducer Temperature: 0℃~80℃;
Humidity: up to 99% Rh,Non-Condensing;
Transmitter: PC/ABS,IP65;
Transducer: Encapsulated Design,IP68;
Transducer Cable: Standard Cable Length:30FT(9m);
|