| Specification |
Accuracy: 0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN6-80;
Sensor: Tube/Flange;
Application: Environmental Protection;
Type: Vortex Flow Meter;
Measuring Media: Liquid;
Measurement Object: Closed Pipeline;
Process Temperature: -100~180°c;
Ambient Temperature: -40~60°c;
Range: 0.67~885nm3/H;
Flange Standard: ANSI;
Flange Material: 316L;
Flange Size: ANSI 2"150RF;
Body Material: Aluminum;
Element Material: 316L;
Mounting Style: Integral;
Power Supper: 24VDC;
Output Signal: 4-20mA;
Output Indicator: Yes;
Electrica Connect: 1/2"NPT;
Explosion Proof: Ex Ia Iict4;
Pressure: 0-50bar;
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Caliber: DN3 - 3000;
Signal Output Function: 4-20mA/Pulse;
Temperature of Medium: -20~+60deg C;
Communication Signal: RS485(Standard), Hart(Optional),GPRS/GSM (Optiona;
Nominal Pressure: 0.6-1.6MPa;
Power Supply: AC22V and DC24V;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Accuracy: 5%F.S.;
Main Application: Water;
Sensor: Clamp-on/External;
Application: Open Channels;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Acoustics;
Cumulative Flow Range: 0~9999999;
Instantaneous Flow Range: 10L/S~100m3/S;
Flow Accuracy: ±5%F.S.;
Blind Distance: 0.06-2m (Depending on Different Sensors);
Range: Default 3m (Customizable);
Probe Material: ABS;
Protection Class: IP65;
Cable Length: 10m Shielded Cable (Customizable);
Host Performance: Chinese 3 O'clock LCD, 18-Bit Keyboard Operation;
Power Supply: AC85~380V, DC11~24V;
Power Consumption: 5W;
Input Signal: Ultrasonic Probe, RS485 Serial Port;
Output Signal: 1 (Standard) or 2 4-20mA, 4 Relays, RS485;
Sensor Mounting Interface: Standard 485 Interface (24V Power Supply)*2;
Data Browsing: Quickly View Hour, Day, Month, and Year Traffic Re;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Accuracy: 5%F.S.;
Main Application: Water;
Sensor: Clamp-on/External;
Application: Open Channels;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Acoustics;
Cumulative Flow Range: 0~9999999;
Instantaneous Flow Range: 10L/S~100m3/S;
Flow Accuracy: ±5%F.S.;
Blind Distance: 0.06-2m (Depending on Different Sensors);
Range: Default 3m (Customizable);
Probe Material: ABS;
Protection Class: IP65;
Cable Length: 10m Shielded Cable (Customizable);
Host Performance: Chinese 3 O'clock LCD, 18-Bit Keyboard Operation;
Power Supply: AC85~380V, DC11~24V;
Power Consumption: 5W;
Input Signal: Ultrasonic Probe, RS485 Serial Port;
Output Signal: 1 (Standard) or 2 4-20mA, 4 Relays, RS485;
Sensor Mounting Interface: Standard 485 Interface (24V Power Supply)*2;
Data Browsing: Quickly View Hour, Day, Month, and Year Traffic Re;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Nature Gas, Corrosive Liquid/Gas, Acid, Alkali, Water Supply and Drainage, Food, Pul;
Size: DN3-DN1000;
Sensor: Clamp-on/External;
Application: Environmental Protection;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Main Application: Water, Wastewater, Acid, Alkali, Water Supply and Drainage, Food, Pul;
Sensor: Clamp-on/External;
Application: Environmental Protection;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
After-Sales Service: ["1 Year","1 Year"];
Warranty: 1 Year;
Size: DN3-DN1000;
Accuracy: ±0.2-0.5%;
Nominal Diameter: DN10~DN1600;
Nominal Pressure: 0.6~4.0MPa (Others Customizable);
Lining Material: Urethane Rubber/Neoprene Tfn/Silicon Fluorine;
Electrode Form: Standard Type/Scraper Type;
Electrode Material: 316L / Hastelloy B & C/Titanium/Tantalum/Platinum;
Medium Temperature1: Polyurethane Rubber -20~70℃;
Medium Temperature2: PTFE-20~120℃;
Measuring Range: 1500:1 Flow Velocity Setting <15m/S;
Protection Class: IP65/IP67/IP68 Optional;
Power Supply: AC220V 50Hz, DC 24V, DC 3.6V;
Output Signal: 0-10mA, 4-20mA, Frequency, Alarm, Pulse Outputs;
Communication Signal: RS232c, RS485, Hart (Optional);
Load Resistance: 0-10mA 0~1.5kΩ, 4-20mA 0~750ω;
Power-off Protection: Internal Non-Power-off Clock;
Ambient Humidity: 5~100%Rh (Relative Humidity);
|