| Specification |
After-sales Service: 1 Year;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: No;
Gaspath System: No;
Detector: UV;
Energy Resolution: ≤7.5%;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Semi Preparative Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: ID10-20mm;
Weight: 45kg;
Working Mde: Manual (Automsapler as Option);
Target Injection Amount: Gram;
Shipment Demesion: 580*460*300mm;
|
After-sales Service: Lifetime Technical Support,Online Service;
Warranty: 1 Year for Transformer Oil Dga;
Appliance: Transformer Oil Dissolved Gas Analysis;
Gaspath System: Double;
Detector: Two Fid and One Tcd;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Application: Dissolved Gas Analysis of Transformer Oil;
Gas Types That Can Be Analyzed: H2, O2, N2, Co, CO2, CH4, C2h4, C2h6 and C2h2;
Power Supply: Battery Charge;
Composition: Portable Chromatograph and Portable Oscillator.;
Control: Embedded Computer;
Tcd: Sensitivity:≥10000mv.Ml/Mg (Benzene;
Fid: Detection Limit:≤3*10-12g/S;
Ignition Mode: Program Automatic Ignition;
|
After-sales Service: Yes;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Single;
Detector: FID;
Spectrometer Detector: Si(Li);
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 2~5mm;
Operation Display: 5.7 Inch Lattice Localization Color LCD;
Temperature Control Region: 6 Road;
Temperature Range: Above Room Temperature 8 Degrees~ 450degree;
Incremental: 1 Degree;
Accuracy: + / - 0.1 Degree;
Temperature Programmed Order Number: 16 Order;
Cheng Sheng Rate: 0.1~39 Degrees/Min;
Gas Control: Mechanical Valve Control Mode, Electronic Flow Con;
External Event: 4 Way; Auxiliary Control Output 4 Road.;
Boot Into The Sample: Manual, Automatic Optional;
|
After-sales Service: Yes;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Single;
Detector: FID;
Spectrometer Detector: Si(Li);
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 2~5mm;
Operation Display: 5.7 Inch Lattice Localization Color LCD;
Temperature Control Region: 6 Road;
Temperature Range: Above Room Temperature 8 Degrees~ 450degree;
Incremental: 1 Degree;
Accuracy: + / - 0.1 Degree;
Temperature Programmed Order Number: 16 Order;
Cheng Sheng Rate: 0.1~39 Degrees/Min;
Gas Control: Mechanical Valve Control Mode, Electronic Flow Con;
External Event: 4 Way; Auxiliary Control Output 4 Road.;
Boot Into The Sample: Manual, Automatic Optional;
|
After-sales Service: Yes;
Warranty: 1 Years;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Single;
Detector: FID;
Spectrometer Detector: Si(Li);
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 2~5mm;
Operation Display: 5.7 Inch Lattice Localization Color LCD;
Temperature Control Region: 6 Road;
Temperature Range: Above Room Temperature 8 Degrees~ 450degree;
Incremental: 1 Degree;
Accuracy: + / - 0.1 Degree;
Temperature Programmed Order Number: 16 Order;
Cheng Sheng Rate: 0.1~39 Degrees/Min;
Gas Control: Mechanical Valve Control Mode, Electronic Flow Con;
External Event: 4 Way; Auxiliary Control Output 4 Road.;
Boot Into The Sample: Manual, Automatic Optional;
|