| Specification |
After-sales Service: 1 Year;
Warranty: 1 Year;
Appliance: /;
Ray Type: /;
Gaspath System: /;
Detector: /;
Energy Resolution: /;
Spectrometer Detector: Si(Li);
Chromatographic Column Length: /;
Chromatographic Column Diameter: /;
Length: 650mm (Customize);
Lnner Surface Treating: Honing; Polishing;
Lnner Surface Roughness: Ra≤0.2um;
Max.Column Bed Length: 300mm;
Max.Pressure: 100 Bar;
Pore Size: 3um;
Material: 316L Ss Woven Mesh;
|
After-sales Service: Online Service;
Warranty: 12momths;
Appliance: Biochemistry;
Ray Type: No;
Gaspath System: Three;
Detector: FID;
Energy Resolution: ≤8%;
Spectrometer Detector: Si(Li);
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Product Name: Laboratory Analysis Gas Chromatography;
Usage: Analytical Chemistry for Separating and Analyzing;
Purpose: Qualitative Analysis, Quantitative Analysis;
Application: Medicine, Petrochemical, Environment, Biochemistry;
Samples: Volatile Organic Compounds;
with Software: Yes;
Temperature Control Area: Column Box, Injector, Detector;
Temperature Control Range: 15 C ~ 399 C;
Ignition Gas: Hydrogen and Air;
Delivery Time: 10working Days;
|
Warranty: 12momths;
Appliance: Biochemistry;
Ray Type: No;
Gaspath System: Three;
Detector: FID;
Energy Resolution: ≤8%;
Spectrometer Detector: Si(Li);
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Capilary Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Product Name: Laboratory Analysis Gas Chromatography;
Usage: Analytical Chemistry for Separating and Analyzing;
Purpose: Qualitative Analysis, Quantitative Analysis;
Application: Medicine, Petrochemical, Environment, Biochemistry;
Samples: Volatile Organic Compounds;
with Software: Yes;
Temperature Control Area: Column Box, Injector, Detector;
Temperature Control Range: 15 C ~ 399 C;
Ignition Gas: Hydrogen and Air;
Delivery Time: 10working Days;
|
After-sales Service: 24 Hour Online Technical Support;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Gaspath System: More;
Energy Resolution: ≤8%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Product Name: Liquid Chromatography;
Model: Bk-Lci5100;
Type: Isocratic Pump;
Flow Rate Range: 0.001-10.000ml/Min, in 0.001ml Increments;
Flow Accuracy: 0.2%;
Flow Precision: Rsd≤0.06%;
Maximum Pressure: 63MPa;
Pressure Accuracy: 3.0%;
Pressure Pulsation: 0.1MPa;
Wavelength Range: 190-800nm;
Wavelength Repeatability: 0.1nm;
Wavelength Accuracy: 1.0nm;
Band Width: 6nm;
Response Time: 0.0s-5s;
Baseline Noise: 0.25×10-5au;
|
After-sales Service: Yes;
Warranty: Yes;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: Fid, Ecd, Pid;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~20cm;
Chromatographic Column Diameter: 1~2mm;
Model: Bk-Gc900;
Temp. Range: Rt+5~450℃;
Temp. Program: 20-Phase;
Max. Temp. Heating Rate: 40℃/Min;
Power Supply: AC220V±10%, 50/60Hz;
Hydrogen Flame Ionization Detector(Fid): Compatible with Packed and Capillary Columns;
Standard Accessory: Fid Detector, Chromatography Workstation Softwar;
Optional Accessory: Sample Injection System;
External Size(L*W*H): 530*502*508mm;
Net Weight: 42kg;
Package Size(W*D*H): 750*710*720mm;
Gross Weight: 60kg;
|