| Specification |
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: CT/PT Analyzer;
Accuracy Grade: 0.2%;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: <9kg;
Power Source: AC220V;
Usage: Class P/Tp CT & Vt;
Output: 0~100vrms,12arms,36A(Peak Value);
Voltage Measurement Accuracy: ±0.2%;
CT Ratio: Range:1~30000;Accuracy:±0.2%;
PT Ratio: Range:1~10000;Accuracy:±0.2%;
Phase: Range:±5min;Accuracy:0.5min;
DC Resistance: Range:0~300ω;Accuracy:2%±2MΩ;
Burden: Range:0~300va;Accuracy:2%±0.2va;
Standard: IEC,Iee;
Model Name: CT PT Analyzer;
Model Type: Hmcop-100p;
Application: Test for Protection Class CT, Protection Class PT;
Power Supply: AC220V;
PT Ratio Accuracy: ±0.2%;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: CT/PT Analyzer;
Accuracy Grade: 0.2%;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: <9kg;
Power Source: AC220V;
Usage: Class P/Tp CT & Vt;
Output: 0~100vrms,12arms,36A(Peak Value);
Voltage Measurement Accuracy: ±0.2%;
CT Ratio: Range:1~30000;Accuracy:±0.2%;
PT Ratio: Range:1~10000;Accuracy:±0.2%;
Phase: Range:±5min;Accuracy:0.5min;
DC Resistance: Range:0~300Ω;Accuracy:2%±2mΩ;
Burden: Range:0~300va;Accuracy:2%±0.2va;
Standard: IEC,Iee;
Model Name: CT PT Analyzer;
Model Type: Hmcop-100p;
Application: Test for Protection Class CT, Protection Class PT;
Power Supply: AC220V;
PT Ratio Accuracy: ±0.2%;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: at Customized;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: LCD;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: at Customized;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Humidity: <=85%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
|