| Specification |
After-sales Service: Suppor for Lifelong;
Warranty: 12months or Extended;
Output Voltage: DC 15V or Customized;
Output Current: 15000A or Customized;
Input Voltage: 0-600V or Customized;
Product Name: Primary Current Injection Test Set;
Standard: ISO;
Material: Alloy;
Power: 220V;
Customized: Customized;
Model Type: Hmslq;
Nickname: Primary Current Injector;
Calibration Report: Support Third Party Calibration Report;
Acceptance: Factory Release Acceptance or Remote-Video;
Can Support Temperature Rising Test: Yes;
Specfication Can Be Customized: Yes;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Weight: 500-1000Kg;
Power Source: Single Phase220V Three Phase 380V, 10 %, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage, Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil, Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 550kv;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
Max Capacity: 1.25kVA;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Weight: 500-1000Kg;
Power Source: Single Phase220V Three Phase 380V, 10 %, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage, Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil, Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 550kv;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
Max Capacity: 1.25kVA;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Weight: 500-1000Kg;
Power Source: Single Phase220V Three Phase 380V, 10 %, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage, Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil, Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 550kv;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
Max Capacity: 1.25kVA;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Capacitive Load;
Display: LCD;
Control: Computer Control;
Weight: 5kgs;
Power Source: AC220V;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/80kv/90kv;
Standard: IEC;
Language: English;
Model: Vlf Hipot Tester with Tan Delta Measuring;
Input Voltage: 220V ±5%;
Frequency: 50Hz/60Hz;
Function1: Vlf Hipot,AC Hipot,DC Hipot, Tan Delat Measuring;
Function 2: Partial Discharge Detect;
|