| Specification |
Type: CT/PT Analyzer;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Weight: <15kg;
Power Source: AC220V;
Maximum Knee Voltage Measurement: 45kv;
Output: 0.1~125V (AC);
Current Output: 0.001-5A(RMS);
Product Name: Current Transformer Testing Equipment;
Power Supply: AC220V±10%,50Hz/60Hz±10%;
Power Output: 300va;
Current Measurement: : 0~10A;
Voltage Measurement: 0~200 V;
Turns Ratio Measurement: Turns Ratio Measurement:;
|
After-sales Service: Support;
Warranty: One Year and Can Be Extended;
Flow: 2000L/H;
Model: Hmzyd-;
Stage: 2;
Working Vacuum: 60PA;
Limit Vacuity: 3 PA;
Working Pressure: ≤0.5MPa;
Electric Heating Power: 15 Kw;
General Power: 18kw;
Inlet (Outlet) Diameter: φ42;
Continuous Working Time: ≥600h;
Time to Failure: ≥8000h;
Working Noise: ≤75dB;
Lift Suction: 30m;
|
After-sales Service: Support;
Warranty: One Year and Can Be Extended;
Flow: 2000L/H;
Model: Hmzyd-;
Stage: 2;
Working Vacuum: 60PA;
Limit Vacuity: 3 PA;
Working Pressure: ≤0.5MPa;
Electric Heating Power: 15 Kw;
General Power: 18kw;
Inlet (Outlet) Diameter: φ42;
Continuous Working Time: ≥600h;
Time to Failure: ≥8000h;
Working Noise: ≤75dB;
Lift Suction: 30m;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Impulse Voltage Generator;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Power Source: 220V+-10%, or 380V+-10% 50/60Hz;
Divider Ratio: 1000:1;
Output Waveform 1: 1.2μS/50μ;
Locking Range: More Than 20%;
Rated Nominal Voltage: 600kv;
Nominal Capacity: 30kj;
Levels of Voltage: 100kv;
Product Name: Impulse Voltage Generator;
Energy: 10kj, 15kj, 20kj, 30kj, 40kj, Ect;
Voltage: 100kv. 200kv, 300kv, 400kv, 600kv, 800kv, etc;
Standard: IEC;
Certificated: ISO, CE;
Lead Time: 30~40 Workind Days;
Waveform: Lightning Waveform, Switching, Chopped, Ect;
Test Sample: Transformer, Circuit Breaker, Insulator;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Impulse Voltage Generator;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Power Source: 220V+-10%, or 380V+-10% 50/60Hz;
Divider Ratio: 1000:1;
Output Waveform 1: 1.2μS/50μ;
Locking Range: More Than 20%;
Rated Nominal Voltage: 600kv,800kv.1000kv,1200kv.1800kv,2100kv;
Nominal Capacity: 30kj/60kj,80 Kj,100kj.120kj,180kj,210kj;
Levels of Voltage: 100kv.200kv;
Product Name: Impulse Voltage Generator;
Energy: 10kj, 15kj, 20kj, 30kj, 40kj, Ect;
Voltage: 100kv. 200kv, 300kv, 400kv, 600kv, 800kv, etc;
Standard: IEC;
Certificated: ISO, CE;
Lead Time: 40 Workind Days;
Waveform: Lightning Waveform, Switching, Chopped, Ect;
Test Sample: Transformer, Circuit Breaker, Insulator;
|