| Specification |
Type: Fire Alarm Host;
Function: Non-Networked;
Usage: Fire, Smoke, Factory/Hotel/School/Office Fire Alarm Control;
Alarm Volume (within 1m): ≥90dB;
Networking Mode: Wire;
Receive Frequency: 229.95MHz;
Wiring Mode: Bus System;
Zones: 1-32;
Power Supply: 110VAC/240VAC;
Battery: 12V2ah*2;
Fire Relay Output: Nc and No;
Fault Relay Output: Nc and No;
Sounder Output: 2 Circuits;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Wiring Mode: Bus System;
Approvals: Lpcb / Ce-CPR;
No. of Loop: 1 Loop;
Material: Flat Sheet Metal;
Weight: 16.70kg;
Protection: 4kv Surge Protection (Built-in);
Input Voltage: 100-240VAC+10%-15%, 50/60Hz;
Indicator: 24 LED Status/30 Zone Indicators;
Network Panel to Panel: 128 Panels-Single Can Bu(Loop);
System Capacity Memory[Non-Volatile]: 1000 Fire Events, 10,000 General Event;
Protocol/Addressing: T&a, Value Range From 1 to 254;
Programmable Relays: 2 Circuits: Normally Open/Close;
Programmable Input: 1 Circuit: Power Limited 24VDC;
Programmable Aux Power: Limited 19-28VDC;
Fixed Outputs: 1 Circuits: Power Limited 18-28VDC;
Display: 7'' TFT Touch Screen;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Wiring Mode: Bus System;
Approvals: Lpcb / Ce-CPR;
No. of Loop: 1 Loop;
Material: Flat Sheet Metal;
Weight: 16.70kg;
Protection: 4kv Surge Protection (Built-in);
Input Voltage: 100-240VAC+10%-15%, 50/60Hz;
Indicator: 24 LED Status/30 Zone Indicators;
Network Panel to Panel: 128 Panels-Single Can Bu(Loop);
System Capacity Memory[Non-Volatile]: 1000 Fire Events, 10,000 General Event;
Protocol/Addressing: T&a, Value Range From 1 to 254;
Programmable Relays: 2 Circuits: Normally Open/Close;
Programmable Input: 1 Circuit: Power Limited 24VDC;
Programmable Aux Power: Limited 19-28VDC;
Fixed Outputs: 1 Circuits: Power Limited 18-28VDC;
Display: 7'' TFT Touch Screen;
|
Type: Fire Alarm Host;
Function: Linkage;
Usage: Auto, Fire, Smoke;
Networking Mode: Linkage;
Wiring Mode: Bus System;
No. of Loop: 1, 2, 4, 6 Loop;
Protection: 4kv Surge Protection(Built-in);
Display: 7'' TFT Touch Screen;
Material: Flat Sheet Metal;
Color: with Outer Glass Door;
Weight: 16.70kg;
Humidity: 0 to 95% Relative Humidity, Non Condensing;
|
Type: Fire Alarm Host;
Function: Linkage;
Usage: Auto, Fire, Smoke;
Networking Mode: Linkage;
Wiring Mode: Bus System;
No. of Loop: 1, 2, 4, 6 Loop;
Protection: 4kv Surge Protection(Built-in);
Display: 7'' TFT Touch Screen;
Material: Flat Sheet Metal;
Color: with Outer Glass Door;
Weight: 16.70kg;
Humidity: 0 to 95% Relative Humidity, Non Condensing;
|