| Specification |
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: Food Analysis;
Gaspath System: Double;
Detector: Sev P10;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 680mm;
Chromatographic Column Diameter: 200mm;
Flow Range: 0.001-10.000ml/Min(Et Step Length 0.001ml/Min);
Flow Precision: Rsd<0.05%;
Max Pressure: 42MPa;
Accuracy: ≤±0.25%(0.001-10ml/Min);
Gradient: 2 or 3;
Dimension: 400mm*300mm*180mm;
Wavelength Range: 190-700nm;
Power Supply: AC 110V/220V, 50Hz/60Hz;
|
After-sales Service: 24/7 Online Service;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Product Name: Oil Gas Chromatograph;
Voltage Range: 0.5~10kv;
Test Current Range: 10μa~1A;
Power Factor: 0.02 < Cos φ < 0.1;
Current Range: 0.5A ~ 15A (Internal), 0.5A ~ 50A (External);
Frequency Measuremen: 45 ~ 65Hz;
Ambient Temperature: -10°c to 50°c;
Ambient Humidity: ≤85℅rh, Non-Condensing;
Operating Power Supply: AC220V ±10%;
|
After-sales Service: 1year;
Warranty: 1year;
Appliance: Analysis furans;
Ray Type: UV Vis;
Gaspath System: Liquid flow system;
Detector: UV Detector;
Energy Resolution: ≤7%;
Spectrometer Detector: UV Detector;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: C18;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 0.2~0.5mm;
|
After-sales Service: Provided;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Chromatograph;
Gaspath System: Double;
Detector: FID;
Energy Resolution: ≤7%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 1~2mm;
Pump Flow Rate Range: 0.001-9.999ml/Min;
Pump Flow Rate Accuracy: 0.5%(1ml/Min, Water, Room Temperature);
Pump Flow Rate Precision: Rsd Less Than 0.08%(1ml/Min, Water, Room;
Pump Pressure Range: Less Than 42MPa;
UV Detector Wavelength Range: 190-700nm;
UV Detector Baseline Noise: Less Than 8*10-6au;
UV Detector Baseline Drift: Less Than 1*10-4au/H;
UV Detector Detection Limit: 4*10-9 G/Ml(Naphthalene/Methyl Alcohol Solvent);
UV Detector Wavelength Accuracy: 1nm;
|
After-sales Service: Provided;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Chromatograph;
Gaspath System: Double;
Detector: FID;
Energy Resolution: ≤7%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 1~2mm;
Pump Flow Rate Range: 0.001-9.999ml/Min;
Pump Flow Rate Accuracy: 0.5%(1ml/Min, Water, Room Temperature);
Pump Flow Rate Precision: Rsd Less Than 0.08%(1ml/Min, Water, Room;
Pump Pressure Range: Less Than 42MPa;
UV Detector Wavelength Range: 190-700nm;
UV Detector Baseline Noise: Less Than 8*10-6au;
UV Detector Baseline Drift: Less Than 1*10-4au/H;
UV Detector Detection Limit: 4*10-9 G/Ml(Naphthalene/Methyl Alcohol Solvent);
UV Detector Wavelength Accuracy: 1nm;
|