| Specification |
Application: Chemical Instrument, Thermal Power, Mechanical Instrument, Length Instrument, Time Frequency Instrument, Electromagnetic Instrument, Radio Apparatus;
Power: Electricity;
Voltage Output: 110V-220V;
Current Output: 40A-80A;
LCD Display: With LCD Display;
Enclosure Rating: IP20 (Standard);
Operating Temperature: -25°C to +60°C;
Storage Temperature: -40°C to +85°C;
Rated Current: 63 a;
|
After-sales Service: Life Time;
Warranty: 12 Months Excellent After-sales Service;
Application: Electromagnetic Instrument, Electrical Calibration;
Power: Electricity;
Voltage Output: Max. 1100V;
Current Output: Max. 22A(33A optional);
LCD Display: With LCD Display;
Customized: Non-Customized;
Accuracy: Class 0.05;
DC voltage output: ±(10 mV ~ 1100 V);
DC current output: ±(3 mA ~ 22 A)(33A optional);
AC voltage output: 3 mV ~ 1100 V;
AC current output: 30 mA ~ 22 A(33A optional);
Sinusoidal wave frequency: 45 Hz ~ 1500 Hz;
Simulated DC resistance: 0 Ω ~ 220 MΩ;
|
After-sales Service: Life Time;
Warranty: 12 Months Excellent After-sales Service;
Application: Electromagnetic Instrument, Electrical Calibration;
Power: Electricity;
LCD Display: With LCD Display;
Customized: Non-Customized;
DC voltage output: +(10 mV ~ 1020 V),-(10 mV ~ 10.4 V);
DC current output: ±(10 μA ~ 10.2 A);
AC voltage output: 10 mV ~ 1020 V;
AC current output: 10 μA ~ 10.4 A;
Sinusoidal Wave frequency: 10 Hz ~ 20 kHz;
Simulated DC resistance: 1Ω ~ 220 MΩ;
|
After-sales Service: Life Time;
Warranty: 12 Months Excellent for Service;
Application: EV charger testing;
Power: Electricity;
Voltage Output: Measurement range: DCV 200V~1000V; ACV 200V~480V;
Current Output: Measurement Range: DCI 1A~300A; ACI 0.1A~80A;
LCD Display: With LCD Display;
Customized: Customized;
DCV measurement: 200V ~ 1000V;
DCI measurement: 1A ~ 300A;
ACV measurement: 200V ~ 480V;
ACI measurement: 0.1A ~ 80A;
Accuracy: Class 0.05;
Charger Interfaces: CCS2, Type 2, etc.;
|
After-sales Service: Life Time;
Warranty: 12 Months Excellent After-sales Service;
Application: Electromagnetic Instrument, Electrical Calibration;
Power: Electricity;
Voltage Output: Max. 1020V;
Current Output: Max. 20.5A;
Thermocouple (TC): S, R, B, K, N, E, J, T;
LCD Display: With LCD Display;
Customized: Non-Customized;
DC voltage output: ±(0 ~ 1020 V);
DC current output: ±(0 ~ 20.5 A);
AC voltage output: 1mV ~ 1020V;
AC current output: 29 μA ~ 20.5 A;
Sinusoidal wave frequency: 10 Hz ~ 500 kHz;
Simulated DC resistance: 0 Ω ~ 1100 MΩ;
|